Clearone Interact Serial Command Guide Manuale Utente Pagina 58

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 61
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 57
Page 53 of 56
VOLBUT Volume Button
This command sets or reports the channel assigned to the volume button or command.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 2
See GroupAndChannels
(Null to query in text)
Group Group 2 2, 5 (O, P)
TEXT FORM DETAILS
COMMAND FORM:DEVICE VOLBUT [Channel Group]
VOLUME Volume Adjustment
This command changes or reports back the gain for the output channel set as the EC reference.
ARGUMENT DETAILS
Name Type Size Values
Value Signed Float 4
-99.90 99.90 dB **
(Null to query in text)
Absol / Rel 0
A = Absolute
R = Relative
Null = Relative
TEXT FORM DETAILS
COMMAND FORM:DEVICE VOLUME [Value] [Absol/Rel]
** Note: Values indicate entry range only. Actual internal range of the gain stage is from 14.00 to 18.00 dB
for the Interact AT and -65.00 to 20.00 dB for the Interact PRO. Absolute values will be limited to the internal
gain range.
ZDIAL DTMF Dialing USB
This command dials a DTMF sequence or reports back the last sequence dialed.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Reserved 2 0
Number String 44
1 44 Chars of ‘0’ ‘9’, ‘A’ ‘D’, *’, ‘#’, ‘,
(Null to query last number dialed in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE ZDIAL <Channel> [Number]