CALLDUR Call Duration
This command indicates how long a call has lasted. If no call is in session, this will report 0. At the time of call
termination, this command will automatically be sent out reporting the duration.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 17 (R)
Reserved 2 0
Duration String 8 String of format HR:MN:SS
TEXT FORM DETAILS
COMMAND FORM:DEVICE CALLDUR <Channel> <Duration>
CAMBAUD Camera Control Baud Rate
This command selects/reports the baud rate of the camera control serial port.
ARGUMENT DETAILS
Name Type Size Values
Value Unsigned Integer 4
4800, 9600, 14400, 19200
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE CAMBAUD [Value]
CAMCTRLMODE Camera Control Port Mode
This command sets / reports the camera control port mode.
ARGUMENT DETAILS
Name Type Size Values
Value Unsigned Integer 4
0 = Sony
1 = Canon
(Null to Query in Text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE CAMCTRLMODE [Value]
CAMFLOW Camera Control Flow Control
This command selects/reports the flow control of the camera control serial port on the unit. Hardware flow
control is implemented using DTR and DSR.
ARGUMENT DETAILS
Name Type Size Values
Value Unsigned Integer 4
0 = Off
1 = On
2 = Toggle
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE CAMFLOW [Value]