CAMPRESETSET Camera Preset Setup
This command sets the current position of a camera as a camera preset. There is no query for this command.
ARGUMENT DETAILS
Name Type Size Values
Preset Unsigned Integer 2 1 10
Channel Channel 1 See GroupAndChannels
Group Group 1 19 (V)
Label String 16
TEXT FORM DETAILS
COMMAND FORM:DEVICE CAMPRESETSET <Preset Channel Group Label>
CAMPRESETSET2 Camera Preset Setup 2
This command sets or reports the current camera preset.
ARGUMENT DETAILS
Name Type Size Values Units
Preset Unsigned Integer 2 1 10
Channel Channel 1 See GroupAndChannels
Group Group 1 19 (V)
Pan Angle Signed Float 2
If Sony, -100 to 100.
If Canon, -100 to 100.
(NULL to Query in Text)
Degrees
Tilt Angle Signed Float 2
If Sony, -25 to 25.
If Canon, -30 to 90.
Degrees
Zoom Angle Signed Float 4
If Sony, 6.6 to 65.
If Canon, 3 to 47.5.
Degrees
Label String 16
TEXT FORM DETAILS
COMMAND FORM: DEVICE CAMPRESETSET2 <Preset>[Channel Group Pan Tilt Zoom Label]
CAMSWITCHLAG Camera Switch Time Lag
This command set the switch time lag for voice tracking.
ARGUMENT DETAILS
Name Type Size Values
Value Unsigned Float 4 0.00 5.00 s
TEXT FORM DETAILS
COMMAND FORM:DEVICE CAMSWITCHLAG [Value]